NC-MQN04ESSP27-2S   (Standard charger + 2pcs of 2700)
Size AA
Quantity   
Inner: N.A. 
Outer 8 pks
Outer carton dimensions: 517(L)×375(W)×135(H)mm
Gross weight: 3.3kg


NC-MQR03RNUEX2-SS   (Refresh charger + 2 pcs of 2700)
Size AA
Quantity   
Inner: N.A. 
Outer 20 pks
Outer carton dimensions: 207(L)×157(W)×280(H)mm
Gross weight: 4.0kg


NC-MQR02N27-UEX   (2hr Quick charger + 2 pcs of 2700)
Size AA
Quantity   
Inner: N.A. 
Outer 20 pks
Outer carton dimensions: 207(L)×157(W)×280(H)mm
Gross weight: 4.4kg

 
 

 

Safety Control Explanation
Charging timer /

Timer control /

Protection timer

  • A pre-set timer to prevent over-charging which will shorten service life of battery.
  • Charging shall be stopped at the time stated in the manual.
  • So, for NC-MQ R02, the rapid charge will stop within 140 minutes from start for charging 2 pcs of HR-3U(2100mAh) which take only 105 min of charging time. This function prevents dry cell battery from causing electrolyte leakage.
Peak cut control /

Peak voltage control

  • This innovative technology protects batteries against overcharging by detecting exactly when the battery has reached full charge.
  • The purpose is to stop quick charging when a battery reached its peak voltage.
Minus delta voltage detection
  • At the point of full charge, battery voltage will show a small but distinctive drop.
  • When this voltage drop is detected by the minus delta voltage detector, charging, will stop. This is another method to prevent overcharging.
Temperature control for charger & battery
  • Built-in sensors monitor battery temperature for both charger & battery to prevent over-charging.
  • Temperature protection for the charger by Power Control IC.
  • Temperature protection for the battery by built-in sensors which monitor the battery temperature to prevent over-charging. When the battery is beyond the specified temperature, charging will be stopped.
Individual charging control
  • This function monitors the voltage of batteries with different capacities to make sure each one is charged properly.
Non-Rechargeable Battery
  • Stop charging if a non-rechargeable battery is accidentally inserted.
Protection / Alkaline 
  • When the battery's voltage charged with 190mA for NC-MQ R02 is beyond the specified voltage, charging will be stopped.
LED Display Explanation
During charge On ( Red  light )
After full charge Off ( Red light goes off )
Abnormal charge condition Blinking ( Red light )

 


 